A dual-bandwearable exposure meter for ...
Type de document :
Communication dans un congrès avec actes
Titre :
A dual-bandwearable exposure meter for personal RF exposure assessment in indoor environments: on-body calibration in a reverberation chamber
Auteur(s) :
Aminzadeh, Reza [Auteur]
Universiteit Gent = Ghent University = Université de Gand [UGENT]
Thielens, Arno [Auteur]
Universiteit Gent = Ghent University = Université de Gand [UGENT]
Gaillot, Davy [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Télécommunication, Interférences et Compatibilité Electromagnétique - IEMN [TELICE - IEMN]
Lienard, Martine [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Agneessens, Sam [Auteur]
Department of Information Technology [INTEC]
van Torre, Patrick [Auteur]
Department of Information Technology [INTEC]
van den Bossche, Matthias [Auteur]
Department of Information Technology [INTEC]
Rogier, Hendrik [Auteur]
Department of Information Technology [INTEC]
Roosli, Martin [Auteur]
Université de Bâle = University of Basel = Basel Universität [Unibas]
Martens, Luc [Auteur]
Joseph, Wout [Auteur]
Universiteit Gent = Ghent University = Université de Gand [UGENT]
Thielens, Arno [Auteur]
Universiteit Gent = Ghent University = Université de Gand [UGENT]
Gaillot, Davy [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Télécommunication, Interférences et Compatibilité Electromagnétique - IEMN [TELICE - IEMN]
Lienard, Martine [Auteur]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Agneessens, Sam [Auteur]
Department of Information Technology [INTEC]
van Torre, Patrick [Auteur]
Department of Information Technology [INTEC]
van den Bossche, Matthias [Auteur]
Department of Information Technology [INTEC]
Rogier, Hendrik [Auteur]
Department of Information Technology [INTEC]
Roosli, Martin [Auteur]
Université de Bâle = University of Basel = Basel Universität [Unibas]
Martens, Luc [Auteur]
Joseph, Wout [Auteur]
Titre de la manifestation scientifique :
2nd URSI Atlantic Radio Science Conference, AT-RASC 2018
Ville :
Gran Canaria
Pays :
Espagne
Date de début de la manifestation scientifique :
2018-05-28
Titre de la revue :
Proceedings of 2nd URSI Atlantic Radio Science Conference, AT-RASC 2018
Date de publication :
2018
Mot(s)-clé(s) en anglais :
DPDE
Discipline(s) HAL :
Sciences de l'ingénieur [physics]
Résumé en anglais : [en]
For the first time, a dual band wearable personal distributed exposure meter (DPDE) is designed. The DPDE is calibrated on-body in a reverberation chamber. The meter consists of four nodes including textile antennas operating ...
Lire la suite >For the first time, a dual band wearable personal distributed exposure meter (DPDE) is designed. The DPDE is calibrated on-body in a reverberation chamber. The meter consists of four nodes including textile antennas operating at 2443 MHz (WiFi 2 GHz) and 2595 MHz (LTE 2600 MHz). The location of the nodes are optimized based on the calibration in a reverberation chamber. The results show that the DPDE has a high antenna-body isolation and thus its performance is less affected by presence of the human body. The measurement uncertainty of the designed DPDE is maximum 4.5 dB in terms of 68% confidence interval of its response. The results are validated in a real office environment for WiFi 2 GHz. The DPDE has a detection limit of 3 μW.m−2 in diffuse fields.Lire moins >
Lire la suite >For the first time, a dual band wearable personal distributed exposure meter (DPDE) is designed. The DPDE is calibrated on-body in a reverberation chamber. The meter consists of four nodes including textile antennas operating at 2443 MHz (WiFi 2 GHz) and 2595 MHz (LTE 2600 MHz). The location of the nodes are optimized based on the calibration in a reverberation chamber. The results show that the DPDE has a high antenna-body isolation and thus its performance is less affected by presence of the human body. The measurement uncertainty of the designed DPDE is maximum 4.5 dB in terms of 68% confidence interval of its response. The results are validated in a real office environment for WiFi 2 GHz. The DPDE has a detection limit of 3 μW.m−2 in diffuse fields.Lire moins >
Langue :
Anglais
Comité de lecture :
Oui
Audience :
Internationale
Vulgarisation :
Non
Projet Européen :
Source :
Fichiers
- https://biblio.ugent.be/publication/8585303/file/8585306.pdf
- Accès libre
- Accéder au document
- 8585306.pdf
- Accès libre
- Accéder au document
- document
- Accès libre
- Accéder au document
- WICA_810a.pdf
- Accès libre
- Accéder au document
- document
- Accès libre
- Accéder au document
- WICA_810a.pdf
- Accès libre
- Accéder au document