Stall Margin Improvement in an Axial ...
Type de document :
Article dans une revue scientifique: Article original
DOI :
Titre :
Stall Margin Improvement in an Axial Compressor by Continuous and Pulsed Tip Injection
Auteur(s) :
Moubogha Moubogha, Joseph [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Margalida, Gabriel [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
DAAA, ONERA, Université Paris-Saclay [Châtillon]
Joseph, Pierric [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Roussette, Olivier [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Dazin, Antoine [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Margalida, Gabriel [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
DAAA, ONERA, Université Paris-Saclay [Châtillon]
Joseph, Pierric [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Roussette, Olivier [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Dazin, Antoine [Auteur]
Laboratoire de Mécanique des Fluides de Lille - Kampé de Fériet [LMFL]
Titre de la revue :
International Journal of Turbomachinery, Propulsion and Power
Pagination :
10
Éditeur :
MDPI
Date de publication :
2022-03
ISSN :
2504-186X
Mot(s)-clé(s) :
Axial compressor
Active flow control
Stall margin improvement
Tip blowing
Energy cost
Mechanical Engineering
Energy Engineering and Power Technology
Aerospace Engineering
Active flow control
Stall margin improvement
Tip blowing
Energy cost
Mechanical Engineering
Energy Engineering and Power Technology
Aerospace Engineering
Discipline(s) HAL :
Sciences de l'ingénieur [physics]/Mécanique [physics.med-ph]/Mécanique des fluides [physics.class-ph]
Résumé :
Stall and surge are strong limitations in the operating range of compressors and thus one of the major limits of jet engine performance. A promising way to push the stability limit of compression machines is to inject a ...
Lire la suite >Stall and surge are strong limitations in the operating range of compressors and thus one of the major limits of jet engine performance. A promising way to push the stability limit of compression machines is to inject a small amount of flow at the blade tip to alter the physical mechanism responsible for stall onset. This study focuses on the experimental performance of such a system. To do so, an axial compressor test bench was equipped with 40 actuators connected to an auxiliary pressurised air supply system. They were able to generate high-speed jet blowing just at the tip of the rotor blades. The opening of each actuator was controlled by an electromagnetic valve. This allowed generating continuous or pulsed jets with frequencies up to 500 Hz at different duty cycles. The performance of the control system was investigated for various control strategies, where the injected flow rate, the injection angle, the number of injectors, the jet frequency and the duty cycle were systematically varied. This paper is concluded by a study of the energy balance of the system for various configurations. To the best of the authors’ knowledge, this constitutes a rarely seen analysis in the literature.Lire moins >
Lire la suite >Stall and surge are strong limitations in the operating range of compressors and thus one of the major limits of jet engine performance. A promising way to push the stability limit of compression machines is to inject a small amount of flow at the blade tip to alter the physical mechanism responsible for stall onset. This study focuses on the experimental performance of such a system. To do so, an axial compressor test bench was equipped with 40 actuators connected to an auxiliary pressurised air supply system. They were able to generate high-speed jet blowing just at the tip of the rotor blades. The opening of each actuator was controlled by an electromagnetic valve. This allowed generating continuous or pulsed jets with frequencies up to 500 Hz at different duty cycles. The performance of the control system was investigated for various control strategies, where the injected flow rate, the injection angle, the number of injectors, the jet frequency and the duty cycle were systematically varied. This paper is concluded by a study of the energy balance of the system for various configurations. To the best of the authors’ knowledge, this constitutes a rarely seen analysis in the literature.Lire moins >
Langue :
Anglais
Comité de lecture :
Oui
Audience :
Internationale
Vulgarisation :
Non
Source :
Fichiers
- https://hal.archives-ouvertes.fr/hal-03789527/document
- Accès libre
- Accéder au document
- https://hal.archives-ouvertes.fr/hal-03789527/document
- Accès libre
- Accéder au document
- document
- Accès libre
- Accéder au document
- LMFL_IJTPP_2022_MOUBOGHA.pdf
- Accès libre
- Accéder au document
- document
- Accès libre
- Accéder au document
- LMFL_IJTPP_2022_MOUBOGHA.pdf
- Accès libre
- Accéder au document