A DSP-Based EBI, ECG, and PPG Measurement Platform
Type de document :
Compte-rendu et recension critique d'ouvrage
DOI :
Titre :
A DSP-Based EBI, ECG, and PPG Measurement Platform
Auteur(s) :
Abdullayev, Anar [Auteur]
Tallinn University of Technology [TalTech]
Rist, Marek [Auteur]
Tallinn University of Technology [TalTech]
Martens, Olev [Auteur]
Tallinn University of Technology [TalTech]
Metshein, Margus [Auteur]
Tallinn University of Technology [TalTech]
Larras, Benoit [Auteur]
JUNIA [JUNIA]
Microélectronique Silicium - IEMN [MICROELEC SI - IEMN]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Frappe, Antoine [Auteur]
Microélectronique Silicium - IEMN [MICROELEC SI - IEMN]
JUNIA [JUNIA]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Gautier, Antoine [Auteur]
Microélectronique Silicium - IEMN [MICROELEC SI - IEMN]
JUNIA [JUNIA]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Min, Mart [Auteur]
Tallinn University of Technology [TalTech]
John, Deepu [Auteur]
University College Dublin [Dublin] [UCD]
Cardiff, Barry [Auteur]
University College Dublin [Dublin] [UCD]
Krivošei, Andrei [Auteur]
Annus, Paul [Auteur]
Tallinn University of Technology [TalTech]
Tallinn University of Technology [TalTech]
Rist, Marek [Auteur]
Tallinn University of Technology [TalTech]
Martens, Olev [Auteur]
Tallinn University of Technology [TalTech]
Metshein, Margus [Auteur]
Tallinn University of Technology [TalTech]
Larras, Benoit [Auteur]

JUNIA [JUNIA]
Microélectronique Silicium - IEMN [MICROELEC SI - IEMN]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Frappe, Antoine [Auteur]

Microélectronique Silicium - IEMN [MICROELEC SI - IEMN]
JUNIA [JUNIA]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Gautier, Antoine [Auteur]
Microélectronique Silicium - IEMN [MICROELEC SI - IEMN]
JUNIA [JUNIA]
Institut d’Électronique, de Microélectronique et de Nanotechnologie - UMR 8520 [IEMN]
Min, Mart [Auteur]
Tallinn University of Technology [TalTech]
John, Deepu [Auteur]
University College Dublin [Dublin] [UCD]
Cardiff, Barry [Auteur]
University College Dublin [Dublin] [UCD]
Krivošei, Andrei [Auteur]
Annus, Paul [Auteur]
Tallinn University of Technology [TalTech]
Titre de la revue :
IEEE Transactions on Instrumentation and Measurement
Pagination :
1-8
Éditeur :
Institute of Electrical and Electronics Engineers
Date de publication :
2023
ISSN :
0018-9456
Mot(s)-clé(s) en anglais :
Digital signal processor (DSP)
electrical bioimpedance (EBI)
electrocardiography (ECG)
impedance cardiography (ICG)
photoplethysmography (PPG)
test and evaluation platform
electrical bioimpedance (EBI)
electrocardiography (ECG)
impedance cardiography (ICG)
photoplethysmography (PPG)
test and evaluation platform
Discipline(s) HAL :
Sciences de l'ingénieur [physics]/Electronique
Résumé en anglais : [en]
A test and evaluation platform has been developed to research and develop solutions and algorithms for joint acquisition, processing, and reasoning from the electrical bioimpedance (EBI), electro-cardiography (ECG), and ...
Lire la suite >A test and evaluation platform has been developed to research and develop solutions and algorithms for joint acquisition, processing, and reasoning from the electrical bioimpedance (EBI), electro-cardiography (ECG), and photoplethysmography (PPG) signals. The solution is based on the low-cost Launchpad of the Texas Instrument TMS320F28379D dual core 16/32-bit digital signal processor (DSP) with 16-bit multichannel analog-to-digital converter (ADC) and several other peripherals (pulse-width modulation (PWM), ADC, timers, I2C, serial peripheral interface (SPI), a lot of static random-access memory (SRAM) and flash memory). In the simplest mode, the platform is used to simultaneously acquire the EBI, ECG, and PPG signals at 1 kHz and send them to the PC by virtual COMport, for further analysis and presentation. The EBI, ECG, and PPG signals are sampled with a 16-bit ADC and have a resolution of more than four decimal digits, with an EBI error of less than 0.002%. In the next stage, various embedded and “at the edge” measurement algorithms will be developed, tested, demonstrated, and evaluated on this platform.Lire moins >
Lire la suite >A test and evaluation platform has been developed to research and develop solutions and algorithms for joint acquisition, processing, and reasoning from the electrical bioimpedance (EBI), electro-cardiography (ECG), and photoplethysmography (PPG) signals. The solution is based on the low-cost Launchpad of the Texas Instrument TMS320F28379D dual core 16/32-bit digital signal processor (DSP) with 16-bit multichannel analog-to-digital converter (ADC) and several other peripherals (pulse-width modulation (PWM), ADC, timers, I2C, serial peripheral interface (SPI), a lot of static random-access memory (SRAM) and flash memory). In the simplest mode, the platform is used to simultaneously acquire the EBI, ECG, and PPG signals at 1 kHz and send them to the PC by virtual COMport, for further analysis and presentation. The EBI, ECG, and PPG signals are sampled with a 16-bit ADC and have a resolution of more than four decimal digits, with an EBI error of less than 0.002%. In the next stage, various embedded and “at the edge” measurement algorithms will be developed, tested, demonstrated, and evaluated on this platform.Lire moins >
Langue :
Anglais
Vulgarisation :
Non
Source :
Fichiers
- document
- Accès libre
- Accéder au document
- A_DSP-based_EBI_ECG_and_PPG_Measurement_Platform.pdf
- Accès libre
- Accéder au document
- document
- Accès libre
- Accéder au document
- A_DSP-based_EBI_ECG_and_PPG_Measurement_Platform.pdf
- Accès libre
- Accéder au document