Titre :
Contact aspiration versus stent retriever in patients with acute ischemic stroke with m2 occlusion in the aster randomized trial (contact aspiration versus stent retriever for successful revascularization)
Auteur(s) :
Gory, Benjamin [Auteur]
Lapergue, Bertrand [Auteur]
Blanc, Raphael [Auteur]
Labreuche, Julien [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Ben Maacha, Malek [Auteur]
Duhamel, Alain [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Marnat, Gaultier [Auteur]
Saleme, Suzana [Auteur]
Costalat, Vincent [Auteur]
Bracard, Serge [Auteur]
Desal, Hubert [Auteur]
Mazighi, Mikael [Auteur]
Consoli, Arturo [Auteur]
Piotin, Michel [Auteur]
Lapergue, Bertrand [Auteur]
Blanc, Raphael [Auteur]
Labreuche, Julien [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Ben Maacha, Malek [Auteur]
Duhamel, Alain [Auteur]
Evaluation des technologies de santé et des pratiques médicales - ULR 2694 [METRICS]
Marnat, Gaultier [Auteur]
Saleme, Suzana [Auteur]
Costalat, Vincent [Auteur]
Bracard, Serge [Auteur]
Desal, Hubert [Auteur]
Mazighi, Mikael [Auteur]
Consoli, Arturo [Auteur]
Piotin, Michel [Auteur]
Titre de la revue :
Stroke
Nom court de la revue :
Stroke
Numéro :
49
Pagination :
461-464
Date de publication :
2018-02-01
ISSN :
0039-2499
Mot(s)-clé(s) en anglais :
stent retriever
safety
confidence intervals
aspiration
cerebral hemorrhage
stroke
thrombectomy
safety
confidence intervals
aspiration
cerebral hemorrhage
stroke
thrombectomy
Discipline(s) HAL :
Sciences du Vivant [q-bio]
Résumé en anglais : [en]
Middle cerebral artery M2-segment occlusions represent an important subgroup of patients with acute stroke with large-vessel occlusion. The safety of mechanical thrombectomy, especially contact aspiration (CA), in such ...
Lire la suite >Middle cerebral artery M2-segment occlusions represent an important subgroup of patients with acute stroke with large-vessel occlusion. The safety of mechanical thrombectomy, especially contact aspiration (CA), in such distal intracranial occlusions is still under debate. We compared reperfusion, adverse events, neurological recovery, and functional outcome of patients with isolated M2 occlusions according to the first-line strategy mechanical thrombectomy devices (CA versus stent retriever [SR]). This is a post hoc analysis of the ASTER trial (Contact Aspiration Versus Stent Retriever for Successful Revascularization). The primary outcome was successful reperfusion at the end of all endovascular procedures, defined as modified Thrombolysis in Cerebral Infarction (mTICI) scores 2b/3. Secondary outcomes were mTICI 2c/3 and mTICI 3, 90-day functional outcome, assessed with the modified Rankin Scale score. Safety outcomes included 90-day mortality and any symptomatic intracerebral hemorrhage. Seventy-nine patients were included: 48 were allocated to the CA group and 31 to the SR group. There were no significant differences between CA and SR groups in reperfusion after all endovascular procedures regarding mTICI 2b/3 (89.6% versus 83.9%; PPPPP First-line mechanical thrombectomy with CA compared with SR did not result in an increased successful revascularization rate in patients with acute stroke with isolated M2 occlusion.Lire moins >
Lire la suite >Middle cerebral artery M2-segment occlusions represent an important subgroup of patients with acute stroke with large-vessel occlusion. The safety of mechanical thrombectomy, especially contact aspiration (CA), in such distal intracranial occlusions is still under debate. We compared reperfusion, adverse events, neurological recovery, and functional outcome of patients with isolated M2 occlusions according to the first-line strategy mechanical thrombectomy devices (CA versus stent retriever [SR]). This is a post hoc analysis of the ASTER trial (Contact Aspiration Versus Stent Retriever for Successful Revascularization). The primary outcome was successful reperfusion at the end of all endovascular procedures, defined as modified Thrombolysis in Cerebral Infarction (mTICI) scores 2b/3. Secondary outcomes were mTICI 2c/3 and mTICI 3, 90-day functional outcome, assessed with the modified Rankin Scale score. Safety outcomes included 90-day mortality and any symptomatic intracerebral hemorrhage. Seventy-nine patients were included: 48 were allocated to the CA group and 31 to the SR group. There were no significant differences between CA and SR groups in reperfusion after all endovascular procedures regarding mTICI 2b/3 (89.6% versus 83.9%; PPPPP First-line mechanical thrombectomy with CA compared with SR did not result in an increased successful revascularization rate in patients with acute stroke with isolated M2 occlusion.Lire moins >
Langue :
Anglais
Audience :
Internationale
Vulgarisation :
Non
Établissement(s) :
CHU Lille
Université de Lille
Université de Lille
Date de dépôt :
2019-12-09T18:17:47Z