Is skin pressure in load carriage over-evaluated?
Document type :
Article dans une revue scientifique: Article original
PMID :
Permalink :
Title :
Is skin pressure in load carriage over-evaluated?
Author(s) :
Dai, X. [Auteur]
Zeng, Xianyi [Auteur]
École nationale supérieure des arts et industries textiles [ENSAIT]
Génie des Matériaux Textiles - ULR 2461 [GEMTEX]
Liu, S. [Auteur]
Hong, Y. [Auteur]
Zeng, Xianyi [Auteur]
École nationale supérieure des arts et industries textiles [ENSAIT]
Génie des Matériaux Textiles - ULR 2461 [GEMTEX]
Liu, S. [Auteur]
Hong, Y. [Auteur]
Journal title :
Journal of Biomechanics
Abbreviated title :
J Biomech
Volume number :
130
Pages :
110854
Publication date :
2021-11-09
ISSN :
1873-2380
English keyword(s) :
Load carriage
Mechanical modeling
Backpack
Skin pressure
Mechanical modeling
Backpack
Skin pressure
HAL domain(s) :
Sciences de l'ingénieur [physics]
English abstract : [en]
Skin pressure is a biomechanical measure widely used in the assessment of load carriage systems. However, because of the complicated contour of human body, the stiffness of the pressure sensor array, and the large range ...
Show more >Skin pressure is a biomechanical measure widely used in the assessment of load carriage systems. However, because of the complicated contour of human body, the stiffness of the pressure sensor array, and the large range of measurable pressures, there is much variability in previously reported results. In this paper, a simple mechanical model for load carriage was proposed, and the skin pressures beneath the shoulder and hip straps were predicted from the strap forces based on Laplace’s law. The proposed model was used to analyze data from literature with an aim to check the reliability of existing pressure measurements. The static and dynamic pressures at five locations on eight subjects wearing a backpack with a 10 kg load, while standing and walking on a treadmill, were measured respectively using pressure sensors of the air pack type. The combination of literature data analysis and experimental testing proved that the existing measurement method of interface pressure in load carriage systems often leads to over-estimation and this might misguide the pressure criteria set for load carriage system usage and design. The proposed model will be useful for quick prediction of the interface pressure in load carriage systems.Show less >
Show more >Skin pressure is a biomechanical measure widely used in the assessment of load carriage systems. However, because of the complicated contour of human body, the stiffness of the pressure sensor array, and the large range of measurable pressures, there is much variability in previously reported results. In this paper, a simple mechanical model for load carriage was proposed, and the skin pressures beneath the shoulder and hip straps were predicted from the strap forces based on Laplace’s law. The proposed model was used to analyze data from literature with an aim to check the reliability of existing pressure measurements. The static and dynamic pressures at five locations on eight subjects wearing a backpack with a 10 kg load, while standing and walking on a treadmill, were measured respectively using pressure sensors of the air pack type. The combination of literature data analysis and experimental testing proved that the existing measurement method of interface pressure in load carriage systems often leads to over-estimation and this might misguide the pressure criteria set for load carriage system usage and design. The proposed model will be useful for quick prediction of the interface pressure in load carriage systems.Show less >
Language :
Anglais
Audience :
Internationale
Popular science :
Non
Administrative institution(s) :
Université de Lille
ENSAIT
Junia HEI
ENSAIT
Junia HEI
Collections :
Submission date :
2023-06-20T01:38:01Z
2024-03-25T12:32:53Z
2024-03-25T12:32:53Z